Most splitters come with two stage pumps over here, Ed.
Al, a constant pressure system shouldn't be constantly relieving pressure. Depending the system might not even require a pressure relief valve. At times of no load the the pump's output should be near 0, only allowing for the pump's...
I don't know what pressure the system runs at. To get the rated tonnage it would need roughly 3600 psi, or 20% over "standard". There isn't any reason a system couldn't be designed to run at that pressure.
I still think the easiest thing would be using a smaller cylinder until you need more...
Assuming American units:
Force= radius x radius x 3.14 x psi
Hydraulic hp= gpm x psi / 1714
Gallons to stroke cylinder= radius x radius x 3.14 x stroke length/ 231
I just got out of my chair and into the bed, so I'll soon be back asleep, but the easiest way to get a faster cycle time is put...